The RTR-57U can collect data from any RTR-51,52,53 and RVR-52A unit as well as from any TR-5 or TR-7 Series unit. Data downloading can be carried out with any RTR unit via wireless communication or by simply placing the unit front down on the communication pad area as done with the TR-5 series units. Data from other types of units can be downloaded via the provided communication cable connection.

Click HERE for a PDF overview of the RTR-5 Series

RTR 51
Specifications
Measurement Channel:  1 Temperature Channel
Internal Temp Sensor  Range:  -40 to 80º C
Measurement Display Resolution:  0.1º C
Measurement Accuracy:  Avg±0.5ºC
Recording Interval: 1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes Total of 15 choices (Excluding Event data)
Recording Capacity:  16,000 Readings x 1 Channel
Recording Mode:  Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full)
LCD Display Items:  Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data
Power:  Lithium Battery (LS14250(SAFT)) x 1 / L Series (Large Capacity Battery Pack) :Litium Battery (LS26500) x 1 / AC Adaptor (sold separately)
Battery Life:  Approx. 6 months / L Series: Approx 2 years and 6 months
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Transmission Range:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Dimensions: H62mm x W 47mm x D19mm(D46.5mm:L Series)(excluding protrusions / antenna length 20mm)
Interface:  Wireless Communication / Optical Communication
Communication Speed:  When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Water Resistance:  IP67 (immersion proof)
Unit Temperature Resistance:  -30 to 80°C ( Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C )
Other:  In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units.



RTR-51 (battery included)
$169.00

RTR-51L (Requires Battery-LC, not included)
$179.00

Battery-LC
$30.00


Quantity:  

RTR 51
RTR 52
Specifications:
Measurement Channel:  1Temperature Channel
External Temperature Sensor:  -60 to 155°C
Measurement Display Resolution:  0.1°C
Measurement Accuracy:  Avg±0.3°C(-20 to 80°C) Avg±0.5°C(-40 to -20°C/80 to 110°C) Avg±1.0°C(-60 to -40°C/110 to 155°C)
Recording Interval:  1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes Total of 15 choices (Excluding Event data)
Recording Capacity:  16,000 Readings x 1 Channel
Recording Mode:  Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full)
LCD Display Items:  Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data
Power:  Lithium Battery (LS14250(SAFT)) x 1 / L Series (Large Capacity Battery Pack) :Litium Battery (LS26500) x 1 / AC Adaptor (sold separately)
Battery Life:  Approx. 6 months / L Series: Approx 2 years and 6 months
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Transmission Range:  Approx. 100m (May vary with conditions)
Dimensions:  H62mm x W 47mm x D19mm(D46.5mm:L Series)(excluding protrusions / antenna length 20mm)
Interface:  Wireless Communication / Optical Communication
Communication Speed:  When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Water Resistance:  IP64 (rated for use in daily life)
Standard Sensor / Input Cable:  TR-5106 (length: Approx.0.6m)x 1
Unit Temp. Resistance:  -30 to 80°C ( Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C )
Other:  In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units.



RTR-52 (battery included)
$194.00

RTR-52L (Requires Battery-LC, not included)
$204.00

Battery-LC
$30.00


Quantity:  

RTR 52
RTR 52PT
Measurement Channel:  1Temperature Channel
External Temp. Sensor:  -199.9 to 600°C
Measurement Display Resolution:  0.1°C
Measurement Accuracy:  ±0.3°C(-199.9 to 80°C) ±0.5°C(80 to 450°C) ±1.0°C(450 to 600°C) (at 0 to 50°C/Sensor accuracy is not included.)
Recording Interval:  1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes Total of 15 choices (Excluding Event data)
Recording Capacity:  16,000 Readings x 1 Channel
Recording Mode:  Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full)
LCD Display Items:  Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data
Power:  Lithium Battery (LS14250(SAFT)) x 1 / L Series (Large Capacity Battery Pack) :Litium Battery (LS26500) x 1 / AC Adaptor (sold separately) 
Battery Life:  Approx. 6 months / L Series: Approx 2 years and 6 months
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Transmission Range:  Approx. 100m (May vary with conditions)
Dimensions:  H62mm x W 47mm x D19mm(D46.5mm:L Series)(excluding protrusions / antenna length 20mm)
Interface:  Wireless Communication / Optical Communication
Communications Speed:  When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Water Resistance:  IP64 (rated for use in daily life)
Standard Sensor / Input:  RTR-05P1 (length: Approx.1m)x 1
Unit Temp Resistance:  -30 to 80°C ( Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C )
Other:  In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units.


RTR-52PT (battery included)
$219.00

RTR-52LPT (Requires Battery-LC, not included)
$229.00

Battery-LC
$30.00


Quantity:  

RTR 52PT
RTR 53
Measurement Channel:  1Temperature and 1 Humidity Channel
External Temp. Sensor:  0 to 55°C
External Humidity Sensor:  10 to 95%RH
Measurement Display Resolution:  0.1°C/1%RH
Measurement Accuracy:  Avg±0.3°C ±5%RH (at 25°C and 50%RH)
Recording Interval:  1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes Total of 15 choices (Excluding Event data)
Recording Capacity:  8,000 Readings x 2 Channel
Recording Mode:  Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full)
LCD Display Items:  Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data
Power:  Lithium Battery (LS14250(SAFT)) x 1 / L Series (Large Capacity Battery Pack) :Litium Battery (LS26500) x 1 / AC Adaptor (sold separately)
Battery Life:  Approx. 6 months / L Series: Approx 2 years and 6 months
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Transmission Range:  Approx. 100m (May vary with conditions)
Dimensions:  H62mm x W 47mm x D19mm(D46.5mm:L Series)(excluding protrusions / antenna length 20mm)
Interface:  Wireless Communication / Optical Communication
Communication Speed:  When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Water Resistance:  IP64 (rated for use in daily life)
Standard Sensor / Input Cable:  TR-3310 (length: Approx.1m)x 1
Unit Temp. Resistance:  -30 to 80°C ( Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C )
Other:  In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units.


RTR-53 (battery included)
$286.00

RTR-53L (Requires Battery-LC, not included)
$296.00

Battery-LC
$30.00


Quantity:  

RTR 53
RVR 52A
Measurement Channel:
    1Voltage Channel
        Input Voltage Range:  0 to 6.5V
        Measurement Display Resolution:  1mV
        Measurement Accuracy:  ±0.5%+5dgt (at 0 to 40
        Input Impedance:  Approx. 1M
        Recording Capacity:  16,000 Readings x 1 Channel
    1Pulse Channel
        Input Voltage Range:  0 to 30V
        Detection Voltage:  Lo: below 0.6V / Hi: above 2V
        Response Time:  30Hz / Approx.15msec or more (over 2.5V)
        Response Polarity:  Response Polarity
        Highest No. of Counts:  Highest No. of Counts
        Input Impedance:  Pu, Ev: Pull-up Resistor Approx.100k
        Recording Capacity: 16,000 Readings x 1 Channel 
    1Event Channel
        Input Voltage Range:  0 to 30V
        Measurement Display Resolution:  1sec.
        Detection Voltage:  Lo: below 0.6V / Hi: above 2V
        Response Time:  1 sec.
        Response Polarity:  Ev: Both Lo -Hi and Hi-Lo
        Input Impedance:  Pu, Ev: Pull-up Resistor Approx.100k
        Recording Capacity: 8,000 Readings x 1 Channel 
Recording Interval:  1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes. Total of 15 choices (Excluding Event data)
Recording Mode:  Endless (Overwrite oldest data when capacity is full) /One-time (Stop recording when capacity is full)
LCD Display Items:  Current Readings / Recording Settings / Battery Life Warning /Over Measurement Range Warning / Amount of Recorded Data
Power:  Lithium Battery (LS14250(SAFT)) x 1 /L Series (Large Capacity Battery Pack) :Lithium Battery (LS26500) x 1 /AC Adapter (sold separately)(*2)
Battery Life(*3):  Approx. 6 months / L Series: Approx 2 years and 6 months
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Dimensions:  H62mm x W 47mm x D19mm(D46.5mm:L Series)(excluding protrusions / antenna length 20mm)
Interface:  Wireless Communication / Optical Communication
Communication Speed:  When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Water Resistance(*4):  IP64 (rated for use in daily life)
Standard Sensor / Input Cable:  RPR-7101 (length: Approx. 1.5m) x 1
Unit Temp. Resistance:  -30 to 80°C ( Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C )
Other:  The RVR-52A includes an internal pre-heat function which sends signals to turn ON / OFF external sensors, etc...in time with the starting of recording. Possible to measure current with the RVR-5203 4-20mA Probe. In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units.
   


RVR-52A (battery included)
$252.00

RVR-52AL (Requires Battery-LC, not included)
$262.00

Battery-LC
$30.00


Quantity:  

RVR 52A
RTR-61
Specifications
Measurement Item:  Temperature
Measurement Range:  - 25 °C to 235°C
Temperature Sensor:  Thermistor
Measurement Accuracy:
Less than 10 °C :   ±1.5°C
10 °C to 40 °C:     ±1.0°C
40 °C to 85 °C:     ±0.8°C
85°C to 110°C:     ±0.5°C
110°C to 130°C :  ±0.8°C
130°C to 150°C :  ±1.0°C
150°C to 180°C :  ±1.5°C
180°C to 200°C:   ±2.0°C
More than 200°C: ±2.5°C
Measurement / Display Resolution:  0.1°C
Measuring / Display Interval:  0.5 seconds
Number of Recorded Data:  1800 data readings
LCD Display:  Date and Time, Measured Value, Battery Life Warning Unit of Temperature (°C/°F) , User, Items
Temp. Judgment LED Display:  Out of Range: Red LED Blinks ,Within Range: Green LED Blinks
Clock Resolution:  Day / Month / Year / Hour / Minute / Second
Clock Accuracy:  Within +/- 1 second per day (at 25°C)
Battery:  AAA Alkaline Batteries (LR03) x 2 (AAA Ni-Cd, Ni-MH Batteries also compatible)
Battery Life:  About 1 month (when used for PUSH recording every 10 minutes for 16 hours a day)
Interface:  Wireless Communication / Optical Communication
Optical:
Communication Speed:  2400bps (When downloading 1 unit of full data: about 2 minutes and 30 seconds)
Wireless:
Wireless Specifications:  ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ]
Communication Speed:  When downloading 1 unit of full data: about 6 minutes
Transmission Range:  Approximately 100m (May vary with conditions)
Antenna:  Internal Type
Unit Water Resistance:  IP64 (dust / splash resistant <rated for use in daily life>)
Dimensions:  146.8mm x 40mm x 37.9mm (excluding sensor part)
Unit Weight:  About 83g (Including 2 AAA batteries; excluding sensor)
Operating Environment:  - 10°C to 60°C


RTR-61-110 - Standard Unit
$418.00

RTR-61-130 - Extended Probe
$439.00

RTR-61-210 - Handheld Probe with Cable
$494.00

RTR-61-230 - Extended Handheld Probe with Cable
$516.00


Quantity:  

RTR-61
RTR-57U Wireless Data Collector
The RTR-57U can collect data from any RTR-51,52,53 and RVR-52A unit as well as from any TR-5 or TR-7 Series unit. Data downloading can be carried out with any RTR unit via wireless communication or by simply placing the unit front down on the communication pad area as done with the TR-5 series units. Data from other types of units can be downloaded via the provided communication cable connection.


Click HERE for the full details in a printable PDF format
Price: $399.00


Quantity:  

RTR-57U Wireless Data Collector
Online Catalog > Thermometers sorted by type > >> Data Loggers > RTR-5 Series of Wireless Dataloggers

Call us at 800-390-0004 for quantity or resale discounts. We will meet or beat any legitimate price you find!